FUNCTION TESTS
Note: Perform the appropriate function tests for
your control system. Determine whether the control
panels on your machine match the ones below or
the ones on page 22. Follow the step-by-step
instructions below the pictures to test all machine
functions.
At the Ground Controls
1 Insert the key and turn to ground control.
2 Pull out the red Emergency Stop buttons at the
ground and platform controls.
Machines with LED diagnostic readout: LED
should read ----.
Note: Machines with LED diagnostic readout
perform a self-check when the power is turned on.
The self-check takes about 5 seconds. Do not
touch the buttons of the ground control panel until
the self-check is done.
3 Models with manual outriggers: Select an
outrigger. Maintain a firm grasp on the outrigger.
Pull the outrigger release handle and lower the
outrigger. Be sure the outrigger lock pin is
locked. Repeat the procedure for each of the
remaining outriggers.
Adjust the outriggers to level the machine and
raise the wheels slightly off the ground. Level
the machine using only the leveling jacks.
Models with hydraulic outriggers: Push and
hold the auto-level button. Push and hold the
extend outrigger button. The outriggers will lower
and adjust to level the machine and raise the
wheels slightly off the ground. Level the
machine using only the outriggers.
4 Check the interlock display lights at the ground
controls and on the turntable. Confirm that all
four lights are on.
Note: If any interlock display light is flashing, the
machine is not level. Adjust the leveling jacks or
use the individual outrigger buttons to level the
machine.
Test Emergency Stop
5 Push in the ground red Emergency Stop button
to the off position.
Result: The power will shut off and all ground
and platform control functions should not
operate.
6 Pull out the red Emergency Stop button to
the on position.
Test Outrigger Interlock
7 Unscrew one leveling jack or use the leveling
buttons to raise one outrigger until the
corresponding interlock display light turns off.
Result: Boom functions should not operate.
8 Return the leveling jack to the previous setting
or use the leveling buttons to lower the
outrigger.
9 Repeat the procedure for each outrigger.
Platform Control Panel