Genie GS-3268 Utility Vehicle User Manual


 
2 Genie GS-2668 DC and Genie GS-3268 DC Part No. 82750
Operator's Manual Third Edition • Third Printing
SAFETY RULES
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Voltage Minimum Safe
Phase to Phase Approach Distance
Feet Meters
0 to 300V Avoid Contact
300V to 50KV 10 3.05
50KV to 200KV 15 4.60
200KV to 350KV 20 6.10
350KV to 500KV 25 7.62
500KV to 750KV 35 10.67
750KV to 1000KV 45 13.72
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
1250 lbs / 567 kg Platform only
950 lbs / 431kg
Extension only
300 lbs / 136 kg
1000 lbs / 454 kg Platform only
700 lbs / 318 kg
Extension only
300 lbs / 136 kg
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Maximum capacity - GS-2668 DC
Platform retracted 1250 lbs 567 kg
Platform extended - Platform only 950 lbs 431 kg
Platform extended - Extension only 300 lbs 136 kg
Maximum occupants - ANSI and CSA 4
Maximum occupants - Australia
Outdoor use 4
Indoor use only 4
Maximum capacity - GS-3268 DC
Platform retracted 1000 lbs 454 kg
Platform extended - Platform only 700 lbs 318 kg
Platform extended - Extension only 300 lbs 136 kg
Maximum occupants - ANSI and CSA 4
Maximum occupants - Australia
Outdoor use 2
Indoor use only 4