Generac Power Systems 004701-0 Portable Generator User Manual


 
4
1. Generator Air Intake
2. Engine Start/Stop Switch
3. Fuse
4. Optional Remote Panel Receptacle (Side View)
5. Generator AC Output Leads (Side View)
6. Fuel Primer Switch
7. Circuit Breaker
8. Starter Contactor
9. Fuel Inlet
10. Fuel Pump (Behind Access Panel)
11. LP Regulator/Solenoid
12. Oil Filter
13. Oil Drain Cap
14. Oil Dipstick
15. Air Filter (Behind Access Panel)
16. Oil Fill
17. Spark Plug
Section 1 – General Information
Recreational Vehicle Generator
Please record the following information from the generator DATA LABEL or information decal.
1. Model Number _____________________ 2. Serial Number __________________
3. kW Rating _________________________ 4. Rated Voltage __________________
*
SERVICE A CCESSPANEL
OIL LEVEL: CHECK DAILY
AIR FILTER: CLEAN PREFILTER
EVERY 100 HOURS.
REPLACE ELEMENT
EVERY 250 HOURS.
OIL & OIL FILTER:
CHANGE EVERY 100
(IF NECESSARY)
EVERY 500 HOURS.
HOURS. REPLACE PLUGS
PLUGS EVERY 100
INSPECT & CLEANSPARK PLUGS:
REPLACEMENT INFORMATION
*
PERFORM MORE OFTEN IN DUSTY CONDITIONS
AIR FILTER LOCATED BEHIND PANEL.
MAINTENANCE SCHEDULE
AIR FILTER P/N: 0D3262
070185OIL FILTER P/N:
SPARK PLUG P/N: 072347
OIL CAPACITY WITH FILTER:
0.8L/0.84QT
TEMPERATURE SAE VISCOSITY
32°F AND HIGHER
10°F TO 100°F
0°F TO 80°F
-20°F TO 50°F 5W-30
10W-30
15W-40
30
WHEN SERVICE OR PARTS ARE NEEDED IN
THE USA OR CANADA, CONTACT THE GENERAC
SERVICE LOCATOR AT 1-800-333-1322.
HOURS. (OR ANNUALLY)
PREFILTER P/N: 0D4511
FUEL FILTER P/N: 087769
FUEL FILTER: CHANGE EVERY 400
HOURS. (OR ANNUALLY)
*
*
PRIME
FUEL
STOP
START
30A
C.B.
15 A
FUSE
CONTROL CENTER
NEG.
BATTERY
FUEL
INLET
BATTERY
POS.
REMOTE
1
2
3
4
5
6
7
8
9
15
11
1213
14/16
17
10
1.1 GENERATOR IDENTIFICATION