Grasp starter grip and pull slowly until you feel some
resistance. Then pull cord out with rapid full arm
stroke. Let rope return slowly. Do Not let rope snap
back against starter.
When engine starts, move choke lever to Half
choke position until the engine runs smoothly and
then to No choke position. If engine falters, move
choke lever to Half choke position until the engine
runs smoothly and then to No choke position.
NOTE: If engine fails to start after 3 pulls, move the
choke lever to No choke position and pull starter
rope again.
NOTE: If the engine fails to start after three (3) pulls,
check for proper oil level in crankcase. Unit is
equipped with a low oil shutdown system.
NOTE: If engine fires, but does not continue to run,
move choke lever to Full choke position and repeat
starting instructions.
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes
after starting.
Plug in and turn on the desired 120 and/or 240 Volt
AC, single phase, 60 Hertz electrical loads.
Do Not connect 240 Volt loads to the 120 Volt
duplex receptacles.
Do Not connect 3phase loads to the generator.
Do Not connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. Add up
the rated watts (or amps) of all loads to be
connected at one time. This total should not be
greater than the rated wattage/amperage capacity of
the generator. See Dont Overload the Generator
on page 10.
Stopping the Engine
Unplug all electrical loads from generator panel
receptacles. Never start or stop engine with
electrical devices plugged in and turned on.
Let engine run at no-load for several minutes to
stabilize the internal temperatures of engine and
generator.
Move engine control switch to Off (o) position.
Close the fuel shutoff valve.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your Generac
generator may experience icing of the carburetor
and/or the crankcase breather system.
In an emergency, use the original shipping box as a
temporary shelter:
Cut off all flaps
Cut out one of the long sides of the box to expose
exhaust side of unit. Ensure a minimum of two feet
clearance between open side of box and nearest
object.
Cut appropriate slots to access receptacles of unit.
Start unit, then place box over it.
IMPORTANT: Remove shelter when temperature is
above 40°F [4°C].
For a more permanent shelter, build a structure that
will enclose three sides and the top of the generator:
Make sure entire muffler-side of generator is
exposed, as shown in Figure 7. Please note that the
unit shown in this figure is a typical unit and may not
exactly portray your unit.
Figure 7  Temporary Cold Weather Shelter
Wind