Generac 13050 Portable Generator User Manual


 
Generac Portable Products 4,200 Watt Generator
8
120/240 Volt AC, 20 Amp Locking
Receptacle
Use a NEMA L14-20 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volts AC at 20 Amps (or
greater) (Figure 8). You can use the same 4-wire cord if
you plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 2,400 watts of power at
20 Amps for 120 Volts OR 4,200 watts of power (4.2 kW)
at 17.5 Amps for 240 Volts. The outlet is protected by a
push-to-reset circuit breaker.
120 Volt AC, 30 Amp Locking Type
Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 30 Amps to
the plug (Figure 9).
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps. The outlet is protected by a 30 Amp
push–to–reset circuit breaker.
Figure 9 — 120 Volt, 30 Amp Locking Receptacle
Figure 8 — 120/240 Volt, 20 Amp Locking Receptacle