Generac 005735-0 Portable Generator User Manual


 
11

The manufacturer does not recommend using any
gasoline containing alcohol (such as “gasohol”).
If using any gasoline containing alcohol, it must
not contain more than 10 percent ethanol, and
it must be removed from the generator during
storage. Do NOT use any gasoline containing
methanol. If using gasoline with alcohol,
inspect more frequently for fuel leaks and other
abnormalities.
2.8 TO START THE ENGINE

Never start or stop engine with electrical devices
plugged into the receptacles AND devices turned
on.
• Unplug all electrical loads from the unit's receptacles before starting
the engine.
Make sure the unit is in a level position.
Open the fuel shut-off valve (Figure 16).
Never operate in an enclosed area or indoors!
NEVER use in the home, or in partly enclosed
areas such as garages, even if doors and
windows are open! ONLY use outdoors and far
from open windows, doors, vents, and in an area
that will not accumulate deadly exhaust.
Figure 16 - Fuel Shut-off Valve
• Locate the Idle Control ON/OFF switch on the control panel and set it
to the “OFF” position (Figure 17).
Figure 17 - Idle Control Switch
• Move engine CHOKE knob outward to “Full Choke” position (Figure
18).
Figure 18 - Full Choke Position
To start engine, press and hold the Start/Run/Stop switch in the “Start”
position. The engine will crank and attempt to start. When the engine
starts, release the switch to the run position.
• When the engine starts, move choke knob to “1/2 Choke” position
until the engine runs smoothly and then fully in to the “Run” position.
If engine falters, move choke knob back out to “1/2 Choke” position
until the engine runs smoothly and then to “Run” position.
NOTE:
If engine fires, but does not continue to run, move choke lever to “Full
Choke” and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against overload
with push-to-reset-type circuit breakers. If amperage rating of any circuit
breaker is exceeded, that breaker opens and electrical output to that
receptacle is lost. Read “Don’t Overload the Generator” carefully.
Operation