Generac 004090-2, 004091-2, 004092-2, 004093-2, 004094-2, 004095-2, 004096-2, 004097-2, 004474-0, 004124-1, 004125-1, 004126-1 004126-1, 004127-1, 004128-1, 004130-1, 004131-1, 00 Portable Generator User Manual


 
6 Generac
®
Power Systems, Inc.
HIGH COOLANT TEMPERATURE SWITCH:
Normally open (N.O.) thermostatic switch has sensing
tip which is immersed in captive coolant. Should
coolant temperature exceed about 230°F (110°C), the
switch contacts close, which causes the engine to shut
down automatically (Figure 6).
Figure 6- High Coolant Temperature Switch
LOW COOLANT LEVEL SWITCH:
Should engine coolant level drop below the level of the
high coolant temperature switch, it is possible for the
engine to overheat without automatic shutdown. To
prevent such overheating without automatic shut down,
the engine has a low coolant level sensor. If the engine
coolant drops too low, the engine automatically shuts
down (Figure 7).
Figure 7 - Low Coolant Level Sensor
OVERSPEED SHUTDOWN:
The CMA circuit board on liquid cooled units receives
AC frequency (rpm) signals directly from the stator AC
power windings, via sensing leads S15 and S16. Should
AC frequency exceed about 72 Hz, circuit board action
will automatically shutdown the engine (Figure 8).
*Rated power of generator is subject to and limited by
such factors as ambient temperature, altitude, engine
condition, and other factors. Engine power will decrease
about 3.5% for each 1000 feet above sea level and will
decrease an additional 1% for each 10°F above 60°F.
Maximum output power of the generator is limited by
maximum engine power.
Section 1 — General Information
Guardian Liquid-cooled 10 kW, 15 kW, 20 kW and 25 kW Generators
SPECIFICATIONS
GENERATOR SPECIFICATIONS
3-Phase 1-Phase
Mode
l 004097 004095 004093 004091 004096 004094 004092 004090
004131 004127 004125 004130 004126 004128 004124
*Rated Max. Cont.
AC Power Output (kW) 25 20 15 10 25 20 15 10
Rated Voltage (volts) 120/240 120/240
Rated Max. Cont.
Current @ 240 V, 1Ø N/A N/A N/A N/A 104.2 83.3 62.5 41.7
Current @ 240 V, 3Ø 75.3 60.2 45.2 30.1 N/A N/A N/A N/A
No. of Rotor Poles 2 4 2 4
Driven Speed of Rotor 3600 3600 1800 1800 3600 3600 1800 1800
Rotor Excitation System Direct excited brush type system
Type of Stator 12 wire reconnectable
Rotor/Stator Insulation Class F
† Models 004474 & 004475 has same specifications
as models 004096 & 004130 below.