Lamp Specification—The Ultra
★★
★★
★Sport floodlight
takes advantage of metal halide lamp technology,
proven by decades of use in all types of lighting
application. It uses an advanced generation of lamps
specifically designed for use in sports lighting.
Offered in a choice of 2000, 1500 or 1000 watts, these
white light sources feature a double-ended design
without an outer bulb, and provide an average rated
life of 3000, 6000 and 10,000 hours, respectively.
These advanced lamps also provide excellent color
rendering with a 4000 degree Kelvin color
temperature. They are designed for an orientation of
horizontal plus or minus 4 degrees, and have no tilt
factor.
Lamp Installation—Ultra
★★
★★
★Sport floodlights are
shipped with lamps installed.
The double-ended metal halide lamp mounts
transversely to a specific orientation by inserting the
lamp ends into pre-focussed ceramic holders. It is
held in place by stainless steel spring clips that snap/
lock in place. The electrical connection of the lamp is
separate from the mechanical support, and is made by
connecting the spade ended-lamp leads to the socket
terminals and tightening with a screwdriver.
8
GE is . . . Sports Lighting!
e
Metal Halide Metal Halide
2000 Watt Double-Ended 1500 Watt Double-Ended
GE Lamp Number MQI/2000/T9/40 MQI/1500/T8/40
Catalog Number—OSRAM Sylvania M2000T9/DE M1500/T9/DE
ANSI Designation U134 U133
Burning Position Horizontal ± 4 Degrees Horizontal ± 4 Degrees
MOL 10.00 Inches (254mm) 10.00 Inches (254mm)
LCL 5.00 Inches (127mm) 5.00 Inches (127mm)
Arc Length 4.25 Inches (108mm) 4.25 Inches (108mm)
Base Ceramic #10 Spade Ceramic #8-10 Spade
Lamp Volts 250 ± 10 Volts 265 ± 10 Volts
Lamp Current 8.5 Amps 6.3 Amps
Ignitor Pulse (Peak) 4000-5000 Volts 4000-5000 Volts
Pulse Width @ 3600 volts One Microsecond One Microsecond
Minimum Pulse Required 4000 Volts 4000 Volts
Initial Lumens 200,000 160,000
Lumens at 100 Hours 100% 100%
Lumens at 40% Rated Life 85% 85%
Average Rated Life 3000 Hours 6000 Hours
Color Temperature 4000° Kelvin 4000° Kelvin
CRI RA=65+ RA=65+
Hot Restart Capability Yes Yes
Lamp Seal Temperature Not to exceed 450 degrees C. Not to exceed 450 degrees C.
Bulb Wall Temperature Not to exceed 950 degrees C. Not to exceed 950 degrees C.