15
GB
5. Cleaning
Always clean your Pressure Sprayer after spraying.
v Fill the Pressure Sprayer with clean water (the water may
contain some washing-up liquid if necessary) and empty out
the water by spraying it through the spray tube in the same
way as when spraying a product.
This cleans the valves, the spray tube and the nozzles.
We recommend that you have your Pressure Sprayer thoroughly
inspected (preferably at a GARDENA Service Centre) after
using it for 5 years.
6. Trouble-Shooting
If the spray jet from the Pressure Sprayer is very weak you
should clean the filter in the container.
Pressure Sprayer Art. No. 867/869
1. Unscrew the container cap.
2. Flip up the filter
7
and rinse under running water.
3. Close the filter
7
and screw the container cap back on.
Pressure Sprayer Art. No. 875 /879/ 880
Remove the filter
W
from the spray tube
3
and clean it.
Problem Possible Cause Remedy
Pump does not build up Container cap is not airtight. v Fasten the container cap
pressure. as tight as it will go
(Art. 867/869).
Safety valve is loose. v Tighten the safety valve.
Hose connection at the container v Tighten the hose connec-
and hand valve is not tight. tions at the container and
hand valve.
Continuous lock enabled on v Take off the permanent lock
handle. at the hand valve.
Pressure Sprayer does not Nozzle is blocked. v Clean the nozzle.
spray although there is
Filter is blocked. v Clean the filter in the
sufficient pressure or only
container (Art. 867/869).
sprays with a weak spray jet.
Clean the filter in the spray
tube (Art. 875/879/880).
It is difficult to open and Container pressure too high. v Release the container pres-
close the container. sure completely by means
of the safety valve.
Grease the container O-ring
with acid-free grease
(Art. 867/869).
If you have any other problems with your Pressure Sprayer please contact GARDENA Customer
Service.
Cleaning the Pressure
Sprayer:
Cleaning the filter:
7
3