FMI BTB18 Log Splitter User Manual


 
2
118843-01
REV. B
02/11
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
Figure 3 - Routing and Installing Flexible Gas Line for 18'' Models
(Log Set Not Shown For Clarity)
5. 18'' Models Only:Toassemblenexexline,insertextubeinto
end of compression nut with small opening. Place sleeve over
endofextubeandintocompressionnut.Repeatforotherend.
Attachnewexiblegaslinetovalveandburnerroutedthrough
grate as shown in Figure 3. It is very important that you route
theexlinethroughthebacklegonthegrate.Itcouldinterfere
withplacementinreplaceifroutedaroundleg.
Checking Gas Connections
WARNING: Test all gas piping and connections, in-
ternal and external to unit, for leaks after installing or
servicing. Correct all leaks at once.
WARNING: Never use an open ame to check for a
leak. Apply a noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
See your owner's manual for complete instructions on checking
your gas connections.
Sleeve
Compression Nut
Compression
Nut
Sleeve
Burner
Valve