Flowtron Outdoor Products MT-300 Series Insect Control Equipment User Manual


 
Page 5
Connect Propane Regulator
1 . Remove the plastic dust cover from your propane
tank valve.
2 . Screw the propane regulator coupling located on
the end of the propane hose onto the tank valve by
turning the black threaded coupling clockwise until
tight. Hand tighten only. See Illustration 4.
Note: Gas will not flow unless connection is tight.
Tighten by hand only.
Using a wrench or
other tool could
damage the regulator
coupling and could
cause a gas leak.
WARNING
Check for gas leaks by wetting the connec-
tions with a solution of soap and water and
watching for bubbles. If bubbles form or if a
bubble grows larger, there is a leak and
connection must be tightened.
Illustration. 4
4 . ( M T-300 series only )
Move your unit to the
desired location in your
yard. Remove catch tray
and grasp housing as
s h o w n .
See trap “Placement”
instructions on pg. 4.
Assembly
Tank Stand (MT-200
series only)
1. Insert tank support strap
into openings in tank stand
as shown. See Figure A.
2. On the underside of the
tank stand, loosen the two
hex nuts located on the
screws which extend from
the sides of the base plate.
Place the slots at the ends
of the tank support strap
over the screws and
secure by tightening the
two nuts. See Figure B.
PowerTrap (MT-200 &
MT-300 series)
1. Insert one end of the post
into the post opening at
the front of the tank stand.
Insert opposite end of
post into the post opening
located at the bottom of
the Flowtron Mosquito
P o w e r Tr a p
®
. Align unit in
relation to the tank stand.
See Illustration 2.
Place a 20 lb. tank on
the tank stand and install
tank wrap around the
tank.
2. Install catch tray by fir s t
inserting the rear of the
tray into the housing.
Then push in upper part of
the latch and raise front of
catch tray into place.S e e
Illustration 3.
3 . Position and screw power
pack to either an outside
or inside wall adjacent to
a electrical outlet (screws
not provided). Run the low
voltage wire either above or below ground from the
power pack to the unit. plug the low voltage wire
into the power cord connector located at the bottom
of the Flowtron Mosquito PowerTr a p
®
. Plug the
power pack into the electrical outlet.
Tank
Cap
Post
Tank
Strap
Tank
Wrap
Tank Stand
Illustration 2
Push
illustration 3
WARNING
Check for gas leaks every time you disconnect and
reconnect a gas fitting.
Be sure there are no sparks or open flame in the
area when you check for leaks.
Do not use a liquid propane tank with a damaged
valve. Have dented or rusty propane tanks checked
by your propane supplier.
Only use regulator supplied with your Flowtron
PowerTrap.
3. Place tank cap on top of tank.
Openings
Tank Stand
Tank Support
Strap
Figure B
Figure A
Base Plate
Tank Strap
Screw & Nut
(2 places)