Fisher & Paykel 80078 Patio Furniture User Manual


 
1. Fix the mounting washers in position, check with a spirit level across the washers to
ensure that they are level.
INSTALLING DUCTING
Note all ducting must comply with local requirements and buildng codes.
2. Mark the position of the decorative chimney at ceiling and wall. Cut the cornice moulding away
if required to enable the chimney to fit flush against the wall.
3 Mark and cut the hole in the ceiling to fit the ducting (160mm). The centre of this hole is
positioned centrally above the canopy and 100mm out from the wall.
INSTALLING CEILING BRACKET
4. Using the screws supplied fix the ceiling bracket to the wall. Check that it is aligned with the
canopy.
FINAL ASSEMBLY
5. Remove the protective plastic covering from all parts including the filters. Fit the canopy on the
mounting washers. Plug in the power cord and check the function of the hood. Unplug the power cord
fix the safety screw, connect and secure the ducting using the cable ties and/or ducting tape.
6. Assemble the telescopic chimney to accurately suit the dimensions required and fix using the screws
supplied to the canopy and the ceiling bracket.
A rubber extrusion is available as an optional extra (part no. 104354GY) to hide any irregularities
between the chimney and the canopy. To fit this extrusion push it over the bottom edge of the
chimney and cut to length.
BEWARE: This edge may be sharp so take care to avoid damage to fingers.
WARNING
All electrical work must be done in accordance with local and/or national electrical codes as
applicable. For safety, this product must be earthed. If you are unfamiliar with methods of
installing electrical wiring, employ the services of a qualified electrican.
Turn off power at service entrance before installing wiring or servicing this product.
The canopy is heavy. Please ensure adequate care when installing the canopy to
prevent personal injury.
The canopy must be installed onto a solid wall or solid studs
lbs
lbs
PRE-INSTALLATION
INSTALLATION OF UNIT
Thank you for purchasing a quality stainless canopy rangehood. We have a
high standard of quality control and each rangehood is tested and approved
before it leaves the factory.
IMPORTANT : Please read prior to installation and operation.
Always switch the power off prior to installing, servicing or cleaning the appliance.
NOTE: Stainless steel is very easily damaged
during installation if abraided or knocked by tools.
Read the instructions before starting the assembly.
Remove the filters to allow access to wall mounting holes.
The unit is designed for 2400mm ceilings. The chimney is
telescopic and is designed for hood installation between 600
and 800mm above the cooking surface.
Ascertain the desired installation height of the canopy.
Note: Optimum installation height is 700mm above the cooking
surface (650mm for gas) but the rangehood can be installed
between 600 and 800mm.
Ducting: Ducting accessories and not supplied. The air outlet
from the motor requires 150mm round ducting which requires
a 160mm diameter hole in the ceiling/wall.
This appliance must be positioned so that the electrical plug
is accessible.
COOKING
SURFACE
914 mm
INSTALLATION
HEIGHT 700mm
CEILING
HEIGHT
2400mm
DUCTED
RECIRCULATED
Before drilling any holes check the wall and ceiling are clear of any electrical cables,
pipes etc. Fixing to a stud/noggin is recommended.
CEILING
BRACKET
FIX SAFETY
SCREW AFTER
MOUNTING
CANOPY
KEYHOLES
IN REAR OF
CANOPY
(SHOWN
DOTTED)
4
5
5
FIX TO SOLID
FRAMING
3
2
1
910mm
100
6
104835 issue B
ECN 05 048
CUT CORNICE
TO CLEAR COVER IF PREFERRED
160mm DIA HOLE
Never use the appliance without the filters.
Please read the notes on general cleaning, especially the filters.
Exhaust air must not be discharged into a heating flue or wall cavity, unless the
cavity is designed for that purpose.
Areas where the rangehood is installed that also have gas, oil or coal fired heaters,
must be well ventilated to prevent a partial vacuum in the room. This includes
gas hobs. (A partial vacuum in the room could result in too high a concentration
of gas in the air).