Echo PB-60HT, PB-46LN, PB-46HT Blower User Manual


 
15
P
OWER
B
LOWER
O
PERATOR
'
S
M
ANUAL
STARTING WARM ENGINE
1. Move throttle lever (A) to start/idle detent position, pull recoil
starter handle (D) 5 times and engine should start. Do not use
choke (C).
NOTE
If engine does not start after 5 pulls, use cold start procedures.
STOPPING ENGINE
1. Move throttle lever to idle detent position and allow engine to run
at idle for a few minutes.
2. Move throttle lever (A) to "STOP" position.
WARNING DANGER
If engine does not stop, move choke lever to closed position to stall
engine. Check and repair stop switch before starting engine again or
serious personal injury may result.
OPERATING BLOWER
WARNING DANGER
Always wear safety glasses, hearing protection, a face filter mask
and take all safety precautions or serious personal injury may result.
Do not point the blower pipe in the direction of people or pets.
Read the Safety Section carefully.
IMPORTANT
To avoid engine damage due to over revving, do not block
blower pipe opening.
A
D