Echo PB-250LN Blower User Manual


 
18 X7501186000
© 10/2014 ECHO Inc.
OPERATION PB-250LN
Starting Cold Engine
1. Stop Switch
Move stop switch (A) away from the STOP position.
2. Throttle Position Lever
Move throttle position lever (B) midway between idle and full
throttle positions.
3. Choke
Move choke (C) to COLD START ( ) (closed) position.
4. Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line.
Recoil starter: Use short pulls - only 1/2 ~ 2/3 of rope for
starting. Do not allow the rope to snap back in. Always hold the
unit firmly.
5. Recoil Starter
Place the unit on a flat, clear area. Firmly grasp throttle handle
with left hand and rapidly pull recoil starter handle/rope (E)
until engine fires, or maximum 5 pulls.
6. Choke
Move choke lever (C) to RUN position, and if necessary,
restart engine.
Note: If engine does not start with choke in RUN position after 5
pulls, repeat instructions 3 - 6.
7. Throttle Trigger
After engine warm up, gradually depress throttle trigger to increase engine RPM to operating speed.
Note: Allow engine to warm up 3 minutes before use.
A
B
C
D
E