Dixon 8000G Series Lawn Mower User Manual


 
34
CARE AND MAINTENANCE
HYDROSTATIC PUMPS:
Before each use, check to be sure that the cooling fins of
the hydrostatic pumps are clean. Excessive accumulation
of oil, dirt, or trash may cause the pumps to overheat.
NEVER WASH ACROSS TOP OF RESERVOIR WITH
WATER OR STEAM. Fill reservoir as required per the
maintenance schedule listed in this book.
HYDROSTAT DRIVE BELT
REPLACEMENT PROCEDURE:
To remove hydrostat pump drive belt:
(The hydrostat pump drive is equipped with a spring
loaded belt take-up).
1. Raise seat. (See instructions on Page 25).
2. Remove hold down bolts from belt cover. Remove
belt cover.
3. Rotate the spring loaded take-up idler towards the
left hand hydro pump to provide belt slack for
removal.
4. Remove belt.
To install hydrostat pump drive belt:
1. Rotate the spring loaded take-up idler towards the left
hand hydro pump.
2. Install belt per diagram.
3. Re-attach belt cover.
4. Return the seat to the operating position.