Dixon 2560 Lawn Mower User Manual


 
34
CARE AND MAINTENANCE
HYDROSTAT OIL MAINTENANCE PROCEDURE:
Check the oil level in hydrostatic transmisison oil reser-
voir after every 25 hours of usage. Clean the oil reser-
voir cap and the area around it prior to removal. Check
the oil level. Oil should be approximately 1-3/8” below
top of oil tank. Replenish as needed with SAE 20W-50
motor oil. DO NOT OVERFILL. When checking the oil
level, be very careful to keep the reservoir clean.
Change the oil in the reservoir and hydrostat transmis-
sion oil filter after the first 100 hours of use. Then
every 500 hours after that. Remove the filter and be
sure all oil has drained from the reservoir. Replace with
a new OEM filter (P/N 7252) and SAE 20W-50 motor oil.
Please dispose of used oil at proper collection centers -
protect your environment