DeVillbiss Air Power Company MGP-1218 Pressure Washer User Manual


 
6
GLOSSARY
GFCI: (GROUND FAULT CIRCUIT INTERRUPTER) This
pressure washer is equipped with a GFCI built into the
plug of the power supply cord. This device provides
additional protection from the risk of electrical shock.
(Figure 1)
FLOW RATE: This is the amount of water that passes
through your wand. (Usually measured in G.P.M., gallons
per minute.).
IDLE MODE: This pertains to the time that the pressure
washer is running without the trigger on the wand en-
gaged to spray. You should never run this pressure
washer for more than 5 minutes without pulling the trigger
to relieve pressure. Running the pressure washer in this
manner would void your warranty.
KICK START: There is a tendancy on new units or units that
have not been used for awhile for the motor to "Hum" briefly
on start-up followed by the Trip-out of the GFCI, sometimes
repeatedly. This is not a defect in the unit. Once the unit
has run awhile it can be restarted without incident. A "Kick
Start" procedure should be performed on any new unit or
units that have not been operated for awhile.
This is done by disconnecting the power
cord and turning the motor shaft by inserting a large
blade straight slot screw driver into the slot located in
the shaft at the rear of the unit (Figure 2). Turn the
shaft two or three times to free any seals that might
be stuck.
Improper connection of the equipment-ground-
ing conductor can result in a risk of electrocu-
tion. Check with a qualified electrician or ser-
vice personnel if you are in doubt as to whether
the outlet is properly grounded. Do not modify
the plug provided with the product—if it will
not fit the outlet, have a proper outlet installed
by a qualified electrician. Do not use any type
of adaptor with this product.
Operating unit with water supply shut off
(without flow of water) will result in
equipment damage.
GROUNDING INSTRUCTIONS & EXTENSION CORDS
GROUNDING: This product must be grounded. If it should
malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric
shock. This product is equipped with a cord having an equip-
ment-grounding conductor and a grounding plug. The plug
must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
GROUND FAULT CIRCUIT INTERRUPTER
PROTECTION: This washer is provided with a ground fault
circuit interrupter (GFCI) built into the plug of the power
supply cord. This device provides additional protection from
the risk of electric shock. Should replacement of the plug
or cord become necessary, use only identical replacement
parts that include GFCI protection.
EXTENSION CORDS: Extension cords are NOT recom-
mended to be used with product. If an extension cord must
be used, the following 3 requirements should be met:
1. 14 guage minimum wire size up to 25 ft. cord.
2. 12 guage minimum wire size up to 50 ft. cord.
3. Use only 3-wire extension cords that have 3-prong
grounding—type plugs and 3-pole cord connectors
that accept the plug from the product. Use only
extension cords that are intended for outdoor use.
These extension cords are identified by a marking
"Acceptable for use with outdoor appliances; store
indoors while not in use." Use only extensioncords
having an electrical rating not less than the rating of
the product. Do not use damaged extension cord and
do not yank on any cord to disconnect. Keep cord
away from heat and sharp edges. Always discon-
nect the extension cord from the receptacle before
disconnecting the product from the extension cord.
Extension cord must be connected to a grounded
outlet equipped with a GFCI (Ground Fault Circuit
Interrupter). There is a risk of Electrocution if exten-
sion cord is not connected to a grounded outlet
equipped with a GFCI.
To reduce the risk of electrocution, keep all
connections dry and off the ground. Do not
touch plug with wet hands. Do not use if cord
is damaged.
RESET
Figure 1
Figure 2
PUSH "RESET" ON
GFCI