Craftsman 9195672101 Pressure Washer User Manual


 
16- ENG
D28236
WAND
If the nozzle becomes clogged with
foreign materials, such as dirt,
excessive pressure may develop. If the
nozzle becomes partially clogged or
restricted, the pump pressure will
pulsate. Clean the nozzle immediately
using the nozzle kit supplied and the
following instructions:
1. Shut off the pressure washer and
turn off the water supply.
2. Disconnect spark plug wire.
3. Pull trigger on gun handle to
relieve any water pressure.
4. Disconnect the wand from the
gun.
5. Remove the nozzle from the end of
the wand with the 2mm allen
wrench provided as shown.
6. Clean the nozzle using the nozzle
cleaner provided or a straightened
paper clip. Insert into the nozzle
end and work back and forth until
obstruction is removed.
7. Direct water supply into nozzle end
to backflush loosened particles for
30 seconds.
8. Reconnect spark plug wire.
9. Reassemble the nozzle to the
wand. Tighten securely to prevent
leaks.
10. Reconnect wand to gun and turn
on water supply.
11. Start pressure washer and place
wand into high pressure setting to
test.
PUMP
This screen filter should be checked
periodically and cleaned if necessary.
1. Remove filter by grasping end and
removing it from water inlet of
pump as shown.
2. Clean filter by flushing it with water
on both sides.
3. Re-insert filter into water inlet of
pump. NOTE: Cone side faces
out.
NOTE: Do not operate pressure
washer without filter properly installed.
Filter Screen
Cleaning Debris
Engine parts should be kept clean to
reduce the risk of overheating and
ignition of accumulated debris.
NOTE: Do not use water to clean
engine parts. Water could contaminate
fuel system. Use a brush or dry cloth.
Combustion Deposits
Every 100-300 hours an Authorized
Warranty Service Center should
remove combustion deposits from the
cylinder, cylinder head, top of piston,
and around valves.
Air Cooling System
Over time debris may accumulate in
cylinder cooling fins and cannot be
observed without partial engine
disassembly. For this reason an
Authorized Warranty Service Center
should clean the air cooling system per
recommended intervals.