Craftsman 833.14334 Insect Control Equipment User Manual


 
SEARSELECTRONICINSECT KILLER - MODEL NO. 833.14334
REF. NO. PART NO. DESCRIPTION QTY.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
554 722
596 1565 P02
567 420
596 784
555 5314 SR
245 6260 P27
596 785
544 5288
544 3750
245 6245 P28
532 30O6
576 4890
505 3370
HANGING RING
THREADED NIPPLE, 1" LONG
NEOPRENE WASHER
REDUCING BUSHING
HOOD
THREAD CUTTING SCREW, F, 8-32 x 3/8
LOCKNUT
GRID SPACER
SPACER INSULATOR
SHEET METAL SCREW_ NO. 8 x 1/2
BALLAST
TRANSFORMER
BULB SOCKET ASSY
552
555
512
552
531
512
571
245
544
245
512
530
553
553
505
5O5
245
557
3369 P03
3534
392 P26
5202
2034
5140
5170
6236 Pll
3749
6245 P12
404 P02
2815 S
2846 P01
2847 P01
3377
4031
6260 P25
5199
REFLECTOR
BULB RETAINER
BULB BOOT WIRE, 26'; LONG
TOP PLATE
STARTER
POWER CORD
STARTER SOCKET
SHEET METAL SCREW, NO. 6 x 3/8
MOUNTING INSULATOR
SHEET METAL SCREW, NO. 6 x 1/2
HV GRID WIRE
BULB, BLACK LIGHT
INNER GRID
OUTER GRID
BASKET ASSY
PHOTOCELL ASSY
THREAD CUTTING SCREW, F, 8-32 x 1/4
OWNER'S MANUAL
1
1
1
1
I
4
1
5
2
9
2
1
2
2
1
2
1
2
1
2
3
3
3
2
2
1
1
1
1
2
1
5
26
15
PROBLEM
A. Bulbs do not light
and no high voltage
on grid.
B. Bulbs light but no
grid high voltage.
C. Grid voltage present
but bulbs do not
light.
O. Intermittent or
continuous sparking
between grids.
POSSIBLE CAUSE
I. No electrical power.
TROUBLESHOOTING AND REPAIR ANALYSIS
CORRECTION
1. Check fuse or circuit breaker.
2. Check extension cord, (If used,)
1. Shorted grids.
1, Lamp(s) not seated properly.
2. Starter defective.
3. Burned-out bulb(s).
1. Gap between grids is too small.
2. Grid clogged with foreign material.
3. Grid not seated in insulaitor.
1. Examine grids to see if inner and outer
grids are free from foreign material, dirt
or a build-up of dead insects.
2. Check to make sure inner grid _nd outer grid
are not touching. Use insulated screwdriver.
1. Check all sockets for proper seating and
alignment. ,,
2. Replace if needed. ,'
3. Replace if needed.
1. Unplug unit and adjust grids by bending
back into alignment using screwdriver blade.
2. Clean grid using an air blower.
3. Look for proper grid seating at all insulators,
Any problems you encounter that are not corrected by the action recommended in this chart should be