STREETWORKS Outdoor Lighting Solutions 173Cooper Lighting
SQUARE STRAIGHT STEEL POLES
Mounting Fixture No. & Accessories
Shaft
3
Wall Height Base Mounting Location Arm (Ground
Square Straight Steel Size Thickness (ft.) Type Finish & Type of Arms Lengths Lug)
SS S5 A 20 SFM 1 XG
Bolt Anchor
Base Circle Bolt Shaft Bolt Net. Max. Fixture
Mtg. Catalog
1, 2
Wall Square Dia. Proj. Size Dia. &. Wt. EPA (Sq. Ft.)
4
EPA (Sq. Ft.)
4
Load—Include
Height Number Thickness (In.) (In.) (In.) (In.) Length (In.) (Lbs.) At Pole Top 2' Above Pole Top Bracket (Lbs.)
MH S BC BP B AB 70 80 90 100 70 80 90 100
10 SSS4A10SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 96 39.8 29.9 23.2 18.4 33.0 24.8 19.3 15.3 150
15 SSS4A15SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 133 19.6 14.4 10.8 8.2 17.2 12.7 9.5 7.3 150
20 SSS4A20SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 152 12.9 9.1 6.5 4.6 11.7 8.2 5.9 4.2 200
25 SSS4A25SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 208 8.7 5.6 3.6 2.1 8.0 5.2 3.3 2.0 200
20 SSS5A20SF .120 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 202 21.9 15.7 11.6 8.5 19.9 14.3 10.5 7.7 200
25 SSS5A25SF .120 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 248 15.5 10.5 7.2 4.8 14.3 9.8 6.6 4.4 200
30 SSS5A30SF .120 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 293 8.2 4.6 2.1 -- 7.7 4.3 2.0 -- 300
35 SSS5M35SF .188 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 480 11.8 7.1 3.8 1.5 11.1 6.6 3.6 1.4 300
25 SSS6A25SF .120 12 1/2 12.5 5 6 1 x 36 x 4 295 24.1 16.8 12.0 8.5 22.2 15.6 11.1 7.8 200
30 SSS6A30SF .120 12 1/2 12.5 5 6 1 x 36 x 4 347 14.0 8.7 5.0 2.5 13.1 8.2 4.7 2.3 300
30 SSS6M30SF .188 12 1/2 12.5 5 6 1 x 36 x 4 505 26.4 18.1 12.5 8.4 24.7 16.9 11.6 7.9 300
35 SSS6M35SF .188 12 1/2 12.5 5 6 1 x 36 x 4 584 19.7 12.7 7.9 4.4 18.6 12.0 7.5 4.2 300
35 SSS6X35SF .250 12 1/2 12.5 5 6 1 x 36 x 4 696 28.9 19.7 13.4 8.9 8.7 18.6 12.7 8.4 300
39 SSS6M39SF .188 12 1/2 12.5 5 6 1 x 36 x 4 647 15.4 9.1 4.8 1.8 14.6 8.7 4.6 1.7 300
39 SSS6X39SF .250 12 1/2 12.5 5 6 1 x 36 x 4 822 23.5 15.4 9.8 5.7 22.4 14.6 9.3 5.4 300
NOTES: 1 Catalog number includes pole with anchor bolts with double nuts (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING).
2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180° from single arm.
3 Shaft size, base plate, anchor bolts and projections may vary slightly—all dimensions nominal.
4 EPA’s based on shaft properties with wind normal to flat. EPA’s calculated using base wind velocity as indicated plus 30% gust factor.
MACHINING FOR RECTANGULAR ARMS [Add as suffix]
Designation Designation Designation Quantity
Letter & Number Letter & Number Letter & Number & Location
M1 E1 Z1 Single
M2 E2 Z2 2 @ 180°
M3 E3 Z3 3 @ 120°
M4 E4 Z4 4 @ 90°
M5 E5 Z5 2 @ 90°
M6 E6 Z6 3 @ 90°
M7 E7 Z7 2 @ 120°
NOTES: Refer to Fixture Drilling Options on page 160.
ACCESSORIES
A=1/2" tapped hub
1
B=3/4" tapped hub
1
C=Convenience outlet
2
G=Grounding lug (max. wire #8 AWG)
H=Additional hand hole and cover—
12" below pole top—90° from hand hole.
NOTES: 1 Location is 3' above base–90° from hand hole.
2 Outlet is located 4' above base and on same side of pole
as hand hole, unless specified otherwise. Receptacle not
included, provision only.
MOUNTING OPTIONS [Add as suffix]
Fixed Tenon Designation O.D. Length
Number (In.) (In.)
1 2 3/8 3 1/2
2 2 3/8 4
3 3 1/2 5
934
7/8''
2 13/16''
3/4'' dia.
hole
(2) 3/8"
dia. holes
3 7/8''
DRILLING PATTERN
Type “M” [RCL, Landau, Galleria and Vision] Type “E” [Concourse III] Type “Z” [Credenza and Cirrus]
3/4'' dia.
hole
(2) 5/8''
dia. holes
2 7/16''
2 5/16''
4 7/8''
O.D.
LENGTH
9/16" [14mm]
dia. hole (3)
4 7/8" [124mm]
4" [102mm]
2 7/16" [62mm]
ORDERING INFORMATION
SAMPLE NUMBER: SSS5A20SFM1XG