PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
OVY40S2D.IES
400-Watt HPS
50,000-Lumen Clear Lamp
Type II-Medium Cutoff
4
3
2
1
0
1
2
3
4
5 4 3 2 1 0 1 2 3 4 5
A
B
C
D
E
FOOTCANDLE TABLE
Select mounting height and read across for footcandle
values of each isofootcandle line. Distance in units of
mounting height.
Mounting Footcandle Values for
Height Isofootcandle Lines
ABC D E
OVY40S2D.IES
25' 3.92 1.96 0.98 0.49 0.20
30' 2.72 1.36 0.68 0.34 0.14
35' 2.00 1.00 0.50 0.25 0.10
40' 1.52 0.76 0.38 0.19 0.08
OVY40S3E.IES
25' 3.92 1.96 0.98 0.49 0.20
30' 2.72 1.36 0.68 0.34 0.14
35' 2.00 1.00 0.50 0.25 0.10
40' 1.52 0.76 0.38 0.19 0.08
4
3
2
1
0
1
2
3
4
5 4 3 2 1 0 1 2 3 4 5
A
B
C
D
E
OVY40S3E.IES
400-Watt HPS
50,000-Lumen Clear Lamp
Type III-Medium Semi-Cutoff
Light Lens
Wattage Source
1
Type III MSCO IV MSCO II MCO III MCO
150 HPS Low N/A N/A OVY15S2D OVY15S3D
Profile (150W) (150W)
200-400 HPS Low OVY40S3E OVY40S4E OVY40S2D N/A
Profile (400W) (400W) (400W)
250-400 MH Low N/A N/A OVY40M2D OVY40M3D
(ED28) Profile (400W) (400W)
250 MV Low N/A N/A OVY25V2D OVY25V3D
(ED28) Profile (250W) (250W)
NOTE: 1 All light sources are clear unless noted otherwise.
PHOTOMETRIC DISTRIBUTION [Curve Number]