Section 5 – Troubleshooting
The following procedures will assist you in determining the potential cause of a machine
operating problem.
Make sure to follow all safety precautions stated in this manual when
doing any work on the machine.
Problem Possible Causes Corrective Action
Starter does not turn the
engine over.
Auxiliary hydraulics lever is
either in Forward or Reverse
position with no hydraulically
powered attachment installed.
Move lever to neutral
position.
Battery is dead. Charge the battery.
If battery does not hold a
charge, replace the battery.
Electrical connections are
corroded or loose.
Check electrical connections
for good contact.
Remove cables from battery
terminals and fully clean
battery terminals and cable
clamps.
If the cable clamps can not be
properly cleaned, replace
connectors.
Relay or starter switch is
defective.
Contact Authorized Service
Dealer.
Engine is in hydraulic lock due
to a cylinder filled with fuel.
Make sure that the spark plug
cables have been moved
away from the engine block
or any other metal surface. A
spark could ignite the fuel
causing a fire or explosion.
Allow engine to cool before
attempting this procedure.
Remove spark plugs and turn
engine over to pump excess
fuel from engine cylinder.
IMPORTANT