Coleman PM0601100 Portable Generator User Manual


 
The generator is equipped with electric start. An Off-On-
Start rotary key switch is provided on the recoil end panel. All
necessary wiring is provided. The battery is customer provided.
See engine manual for wiring diagram (3A Charge Coil), and
additional information.
The charging system of the unit is supplied by the
starter/alternator of the engine. 12 volts DC is constantly
charging the battery when the unit is running . Disconnecting
the battery will stop the charging of the battery.
Before charging a storage battery, check the electrolyte
fluid level in all the cells. (Sealed batteries do not require
checking). Add distilled water to each cell if necessary, to bring
the level back up to the manufacturers required level.
WARNING: Storage batteries give off
EXPLOSIVE hydrogen gas while charging. Do
not allow smoking, open flames, sparks, or
spark producing equipment in the area while
charging.
WARNING: Battery electrolyte fluid is
comprised of sulfuric acid that can be very
dangerous and cause severe burns. Do not
allow this fluid to contact eyes, skin, clothing,
etc. If contact or spillage does occur, flush
the area with water immediately.
CAUTION: This battery charging system is
intended to recharge weak batteries, not to
"boost start" vehicles. Do not overcharge
battery or leave battery unattended.
CAUTION: Do not continue to charge a
battery that becomes hot or is fully charged.
Coleman Powermate, Inc. recommends a 12 V battery with
at least 235 cranking amps, Model U1L, Lawn and Garden
Battery. Place the battery in the position provided. Place the
spacers and washers on the bolts, then place the bolts through
the loops on the Hold-Down bracket. Place the assembly over
the battery and place the bolts through the holes on the battery
pan and tighten down the Hold-Down assembly with the 1/4-20
nuts provided.
Spacers may be removed depending on the battery height.
WARNING: Batteries contain sulfuric
acid (when filled). May contain explosive
gasses. Always abide by safety warnings
provided with the battery.
-Keep sparks, flame and cigarettes away.
-Hydrogen gas is generated during
charging and discharging.
-Always shield eyes, protect skin and
clothing when working near batteries.
Connect the red 8 ga. battery lead to the positive (+)
battery post and the black 8 ga. battery to the negative (-)
battery post with the bolts and nuts provided.
ItemDescriptionQty.
A.*Bolt, 1/4-20 X 8”2
B.*Washer 1/42
C.*Spacer2
D. Hold Down bar (P/N 0036525.02)1
E.*Nyloc nut, 1/4-202
* These are standard parts available at your local hardware
store.
3
English
DC FEATURES
BATTERY INSTALLATION
ELECTRIC START WIRING
BATTERY KIT PARTS LIST