Chauvet MIST-PAR80 Landscape Lighting User Manual


 
Operating Instructions
COLORmist System User Manual 6 2005-10-10/18:36
Hanging Clamp
Mounting
Bracket
SETUP
Power
Warning! Verify that the power indicator label on your unit matches the line voltage applied.
All fixtures must be connected to circuits with a suitable Earth Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixtures specifications chart.
A fixtures listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixtures
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE PIN INTERNATIONAL
BROWN
Live L
BLUE
Neutral N
YELLOW/GREEN
Earth EG (Ground)
Mounting (MIST-PAR80)
Orientation
This fixture can be mounted on a truss using a clamp in any position
or on a strut system for track style lighting.
Rigging
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.
1. Align the clamp screw with the center hole on the yoke and tighten.
2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.
3. Adjust the angle on the yoke arm as necessary.
Mounting (MIST-PAN)
The COLORmist Panel can be
surface mounted directly using its
fastening hinge located directly behind
the unit or utilizing the surface
mounting bracket especially made to
fit. The bracket can be surface
mounted first then later the panel can
be mounted onto the bracket.