4. OPERATING INSTRUCTIONS
This mode will allow you to control the fogger manually, set the fog machine to run continuously, or
to set the fog machine to run off bursts with adjustable interval and duration settings.
Manual Remote Operation (FC-M) (Standard)
1. Plug in the fog machine to power.
2. Plug in the M remote to the Manual Controller socket on the rear of the fog machine.
3. Press the single button located on the remote to trigger the fog output.
The button is momentary, which means that the fog machine will only output while the
button is pressed. Once the button is released, the fog will stop outputting.
Timer Remote Operation (FC-T) (Optional)
1. Plug in the fog machine to power.
2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine.
3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should
light, indicating activation of function.
4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position.
The INTERVAL is the time between bursts of fog.
The DURATION is the time that the fog machine will run during the burst.
Duration
Adjustment
Interval
Adjustment
Timer LED
Indicator
Manual
Momentary
LED
Manual/Power
LED
Manual control
Momentary
Continuous
Latching Button
Timer Latching
Button