Fuel
Fuel capacity is 5.7 gallons (21.5 L). Use regular
unleaded gasoline with a minimum octane rating of 85
and an ethanol content of less than 10% by volume.
Generator Specifications
Model ........................... 41430
Running Wattage .................7500 Watts
Starting Wattage .................9375 Watts
AC Load ...................... 120/240 V
Phase ............................Single
Frequency .........................60 Hz
Fuel Capacity ............. 5.7 gallons (21.5 L)
Gross Weight ............. 212.5 lbs (96.4 kg)
Net Weight .................199 lbs (90.3 kg)
Height ................ 25.2 inches (64.1 cm)
Width .................27.2 inches (69.1 cm)
Length. . . . . . . . . . . . . . . . . . 29.9 inches (76 cm)
SPECIFICATIONS
Engine Specifications
Model ............................ 190F
Displacement .......................420cc
Type ........................4-Stroke OHV
Start Type ....................Electric Start
Maintenance Valve Clearance
Intake: 0.10 – 0.15 mm (0.004 – 0.006 in.)
Exhaust: 0.15 – 0.20 mm (0.006 – 0.008 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
Spark Plugs
OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.6 - 0.8 mm or
(0.024 - 0.031 in.).
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 1.16 qt. (1.1 L).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.