Maintenance
14 Rev 41351-20091106
Maintenance
The owner/operator is responsible for all
periodic maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void
your warranty.
WARNING
Improper maintenance will void your warranty.
Complete all scheduled maintenance in a
timely manner. Correct any issue before
operating the generator.
NOTE
For service or parts assistance, contact our help
line at 1-877-338-0999.
Engine Maintenance
To prevent accidental starting, remove and
ground spark plug wire before performing
any service.
Oil
Change oil when the engine is warm. Refer
to the oil specification to select the proper
grade of oil for your operating environment.
1. Remove the oil drain plug with a 15 mm
socket and extension.
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fill cap/dipstick to add oil.
5. Add 1.16 qt (1.1 L) of oil and replace oil
fill cap/dipstick.
6. Dispose of used oil at an approved waste
management facility.
Spark Plugs
1. Remove the spark plug cable from the
spark plug.
2. Use the spark plug tool that shipped
with your generator to remove the plug.
3. Inspect the electrode on the plug. It
must be clean and not worn to produce
the spark required for ignition.
4. Make certain the spark plug gap is 0.7 -
0.8mm (0.028 - 0.031 in.).
5. Refer to the spark plug recommendation
chart when replacing the plug.
6. Carefully thread the plug into the
engine.
7. Use the spark plug tool to firmly install
the plug.
8. Attach the spark plug wire to the plug.