SPA TROUBLESHOOTING
25
If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and “OPERATION” instructions in this manual. If this doesn’t help
you correct the problem, follow the appropriate instructions below. If the problem still is not resolved, call your Caldera
®
dealer.
GENERAL OPERATION TROUBLESHOOTING GUIDE
Entire spa is inoperative
For high limit,display shows
“____
____”
Spa does not heat; jets and
light operate
(Display shows
“____ or _._._._
____ _._._._”
Jets weak or surging
(Display shows “_._._._
_._._._”)
Light inoperative
Power failure / not plugged in
GFCI tripped
Heater high-limit thermostat tripped
Pressure switch tripped
Pressure switch senses flow through heater
even though the jet pump is off
Spa water level too low
Filters clogged / suction screens clogged
Jet nozzles closed / Air valve closed
Bad connection
Heater high limit thermostat tripped
System Controls
Display shows “- - - -
- - - -”
(Entire spa inoperative)
Check power source
Reset GFCI; call for service if it will not reset.
Disconnect power for at least thirty seconds to reset heater high limit. If it
will not reset, check for clogged filter. If tripping continues, call for service.
Check for clogged filter. The pressure switch will reset when the flow of
water through the heater has been restored. Call for service if the pressure
switch trips frequently.
Contact an Authorized Service Technician
Add water
Clean filters / Clean suction screens
Open jet nozzles / Open air valve
Contact an Authorized Service Technician
Disconnect power to the spa for at least thirty seconds to reset the heater
high-limit. If tripping continues, clean the filter, then if tripping still occurs,
call for service.
Contact an Authorized Service Technician
Problem Probable causes Solutions
Water temperature
significantly different from
display temperature.
Display shows flashing
“READY” icon
Priming the pump(s): Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets, the pump may not be
properly primed. To correct, perform the following procedures:
• Turn off power to the spa at the breaker and remove the equipment compartment door (as seen on page 24).
• Loosen the union on the top of the pump(s) (as seen on page 24) to allow the air to escape, the hand-tighten the union(s).
• Turn power back on, activate the pump and check to make sure union is tight enough to keep it from leaking. Re-install pump and equipment
doors.