Cal Spas A844B Hot Tub User Manual


 
10
Testing the GFCI Breaker
Test the GFCI breaker prior to
rst use and periodically when the
spa is powered. To test the GFCI
breaker follow these instructions
(spa should be operating):
Press the TEST button on the 1.
GFCI. The GFCI will trip and
the spa will shut off.
Reset the GFCI breaker by 2.
switching the breaker to the full
OFF position, wait a moment,
then turn the breaker back on.
The spa should have power
again.
Conguring the 6300
Control System
The 6300 control system requires
higher power than other 240V sys-
tems. Dip switch #10 is factory set
in the ON position. This causes the
heater to shut off when any pump
is running in high speed. To allow
the heater to continue operating,
dip switch #10 must be set to the
OFF position.
To ensure your spa functions prop-
erly, ensure the following steps are
performed before starting your spa:
When installing the electrical
system, use a 60 amp GFCI.
Follow the GFCI wiring diagram
on the next page.
Have your dealer or installer
set dip switch #10 to the OFF
position on the circuit board as
shown below.