120 Volt Electrical Installation
Always follow applicable local, state and federal
codes and guidelines.
Use only a dedicated electrical line with a 20-amp
breaker.
Cord-and-plug connections may not use a cord
longer than 15 ft (4.6 m) and must be plugged into
a dedicated 20-amp GFCI connection. Do not use
extension cords!
Always use a weatherproof-covered receptacle.
Receptacle shall be located not less than 5 ft (1.5 m)
from and not exceeding 10 ft (3.0 m) from the inside wall of the spa.
Do not bury the power cord.
If your cord becomes damaged, replace it before next usage.
All 120V spas must have a GFCI. This can be either a 20-amp GFCI
receptacle or a GFCI cord and plug kit as shown at right (CKIT110 - P/N
ELE09700086).
Testing the GFCI Breaker
Test the GFCI plug prior to rst use and periodically when the spa is
powered. To test the GFCI plug version, follow these instructions. (Spa
should already be plugged in and operational.)
Press the TEST button on the GFCI. The GFCI will trip and the spa will 1.
stop operating.
Press the RESET button on the GFCI. The GFCI will reset and the spa 2.
will turn back on.
The spa is now safe to use.
If the GFCI trips while the spa is in use, press the RESET button. If the
GFCI does not reset, unplug the spa and call your local Cal Spas
®
dealer
for service. DO NOT USE THE SPA!