Buhler 2335 Lawn Mower User Manual


 
SECTION 3 - LUBRICATION AND MAINTENANCE
3-46
EVERY 500 HOURS
Loosen and remove the two hose clamps
securing the suction hose, 1, to the suction
screen port. Remove the suction hose. Unscrew
the suction screen, 2, from the top of the
hydraulic tank and remove it. Cover the hole in
the tank so contaminants cannot enter.
The suction screen can be washed in a cleaning
solvent to remove any debris accumulated in it.
Reinstall the suction screen into the top of the
tank and tighten securely. Reinstall the suction
hose onto the steering pump and suction screen
and tighten the hose clamps to ensure that no air
can enter the hydraulic system.
Figure 3-64
OPERATION 42
Clean the Hydraulic Reservoir Breather
Clean the hydraulic reservoir breather, 1, so that
the hydraulic system can breathe properly.
Remove the breather from its mounting bolt and
unscrew the breather from its hose. Clean it out
using low pressure air 1.7 bar (25 PSI) or less.
Reinstall the hose and replace the breather in its
mounting location.
Figure 3-65
1