Home Standby - 7kW - 12kW - 15kW
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of BRYANT’s success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose BRYANT with the confidence that these systems will provide
superior performance.
TEST CRITERIA:
>
PROTOTYPE TESTED
>
SYSTEM TORSIONAL TESTED
>
NEMA MG1-22 EVALUATION
>
MOTOR STARTING ABILITY
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE
REGULATION. This state-of-the-art power maximizing regulation
system is standard on all BRYANT models. It provides optimized
FAST RESPONSE to changing load conditions and MAXIMUM
MOTOR STARTING CAPABILITY by electronically torque-matching the
surge loads to the engine.
SINGLE SOURCE SERVICE RESPONSE from BRYANT’s dealer
network provides parts and service know-how for the entire unit, from
the engine to the smallest electronic component. You are never on
your own when you own a BRYANT system.
BRYANT TRANSFER SWITCHES. Long life and reliability are
synonymous with BRYANT systems. One reason for this confidence is
that the BRYANT product line includes its own transfer systems and
controls for total system compatibility.
FEATURES
Air-Cooled Gas Engine Generator Sets
Continuous Standby Power Rating Model ASPAS1BBA007 - 7kW 60Hz
Model ASPAS1BBA012 - 12kW 60Hz
Model ASPAS1BBA015 - 15kW 60Hz
INCLUDES:
• Automatic Transfer Switch
with Built-In Emergency Load Center
• Pre-wired External Connection Box
• Flexible Fuel Line
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• GFCI duplex outlet & 12Vdc outlet
• UL Listed to Canadian safety standards
• 2 Year Limited Parts and Labor Warranty
TRANSFER SWITCH &
Model ASPAS1BBA007 Model ASPAS1BBA012 Model ASPAS1BBA015
EMERGENCY LOAD CENTER (7kW) (12kW) (15kW)
No. of Poles 2 2 2
Current Rating (amps) ......................................................100 ..........................................100 ......................................... 100
Voltage Rating (VAC) ....................................................... 250 ......................................... 250 ......................................... 250
Utility Voltage Monitor (fixed)
-Pick-up ...........................................................................
70% ........................................ 70% ....................................... 70%
-Dropout .........................................................................
60% ....................................... 60% ....................................... 60%
Return to Utility ....................................................... approx. 13 sec .......................approx. 13 sec. ....................... approx. 13 sec.
Exerciser weekly for 12 minutes .................................. Standard .................................Standard .................................Standard
UL Listed ...................................................................... Standard .................................Standard .................................Standard
Dimensions (H” x W” x D”) .......................................26.5 x 12.5 x 7 ...................... 26.5 x 12.5 x 7 .......................26.5 x 12.5 x 7
Total of Pre-wired Circuits .................................................. 8 ............................................ 10 ...........................................12
No. 15A 120V .......................................................... 5 ............................................ 3 ........................................... 5
No. 20A 120V .......................................................... 1 ............................................ 3 ........................................... 3
No. 15A 240V .......................................................... - ............................................ - ........................................... -
No. 20A 240V .......................................................... - ............................................ 1 ........................................... 1
No. 30A 240V .......................................................... 1 ............................................ 1 ........................................... 1
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts ...................................10,000 .....................................10,000 ......................................10,000
BRYANT, INC. • 7310 WEST MORRIS STREET • INDIANAPOLIS, IN 46231 • www.bryant.com
Printed in USA 10.05 CATALOG NO. SS-ASPAS07-02 All specifications are subject to change without notice.
Mechanical Dimensions (in inches)
Current No. of Height Width Depth
Rating Poles H1 H2 W1 W2
100 UL Listed 2 26.5 29.25 8.14 12.5 7
W1
W2
H1
H2
Terminal Wire Ranges
ATS Rated Amps Switch Terminal Neutral Lug/Stud Ground Lug
100A 2-Pole UL 1 x 1/0-12 1 x 3/8-16 Stud 1 x 2/0-14
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated or
silver alloy to resist welding and
sticking.
• NEMA 1 enclosure is standard on
the 100 amp switch.
Home Standby - 7kW - 12kW - 15kW