Briggs & Stratton 195764GS Pressure Washer User Manual


 
15
Check In-Line Filter
Refer to Figure 18 and service the in-line filter if it
becomes clogged, as follows:
1. Detach spray gun and nozzle extension from high
pressure hose. Detach nozzle extension from spray
gun and remove o-ring and screen from nozzle
extension. Flush screen, spray gun, and nozzle
extension with clean water to clear debris.
2. Place in-line filter screen into threaded end of nozzle
extension. Direction does not matter. Push screen in
with eraser end of pencil until it rests flat at bottom of
opening.Take care not to bend the screen.
3. Place o-ring into recess. Push o-ring snugly against in-
line filter screen.
4. Assemble nozzle extension to spray gun, as described
earlier in manual.
Nozzle Maintenance
A pulsing sensation felt while squeezing the spray gun
trigger may be caused by excessive pump pressure.The
principal cause of excessive pump pressure is a nozzle
clogged or restricted with foreign materials, such as dirt,
etc.To correct the problem, immediately clean the nozzle
following these instructions:
1. Shut off engine and turn off water supply.
2. Remove nozzle from end of nozzle extension.
3. Remove in-line filter from other end of nozzle
extension.
4. Use a small paper clip to free any foreign material
clogging or restricting nozzle (Figure 19).
5. Using a garden hose, remove additional debris by back
flushing water through nozzle extension (Figure 20).
Back flush between 30 to 60 seconds.
6. Reinstall nozzle and in-line filter into nozzle extension.
7. Reconnect nozzle extension to spray gun.
8. Reconnect water supply, turn on water, and start
engine.
9. Test pressure washer by operating with each quick
connect nozzle.
O–Ring Maintenance
Purchase an O–Ring/Maintenance Kit, part number
191922GS by contacting the nearest authorized service
center. It is not included with the pressure washer.This kit
includes replacement o-rings, rubber washer and water
inlet filter. Refer to the instruction sheet provided in the kit
to service your unit’s o-rings.
Use wire here
to remove
debris.
Figure 19 — Nozzle Maintenance
Figure 20 — Backflushing the Nozzle Extension
Section 5: Maintenance
Nozzle Extension
Filter Screen
O-ring
Figure 18 — Clean In-Line Filter