Briggs & Stratton 030212 Portable Generator User Manual


 
TROUBLESHOOTING
14
TROUBLESHOOTING
Problem Cause Solution
Engine is running, but no AC
output is available.
1. Circuit breaker is open.
2. Poor connection or defective
cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. Contact Briggs and Stratton
service facility.
Engine runs good but bogs down
when loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Disconnect shorted electrical
load.
2. See "Don't Overload Generator".
3. Contact Briggs and Stratton
service facility.
Engine will not start; or starts
and runs rough.
1. Out of petrol.
2. Petrol valve is in the "Closed"
position.
3. Low oil level.
1. Fill petrol tank.
2. Turn petrol valve to the "Open"
position.
3. Fill crankcase to proper level.
Engine shuts down during
operation.
1. Out of petrol.
2. Low oil level.
3. Generator tipped at angle.
1. Fill petrol tank.
2. Fill crankcase to proper level.
3. Place generator on level surface.
Engine lacks power. Load is too high. See "Don't Overload Generator".