MAINTENANCE
16
Nozzle Maintenance
A pulsing sensation felt while squeezing the spray gun
trigger may be caused by excessive pump pressure.The
principal cause of excessive pump pressure is a spray tip
clogged or restricted with foreign materials, such as dirt,
etc.To correct the problem, immediately clean the spray tip
following these instructions:
1. Shut off engine and turn off water supply.
2. Remove spray tip from end of nozzle extension.
3. Use a small paper clip to free any foreign material
clogging or restricting spray tip (Figure 18).
4. Using a garden hose, remove additional debris by back
flushing water through nozzle extension (Figure 19).
Back flush between 30 to 60 seconds.
5. Reinstall spray tip into nozzle extension.
6. Reconnect nozzle extension to spray gun.
7. Reconnect water supply, turn on water, and start
engine.
8. Test pressure washer by operating with each quick
connect spray tip.
O–Ring Maintenance
Through the normal operation of your pressure washer,
o–rings are used to keep the connections of the hoses and
spray gun tight and leak–free.These o-rings may become
worn or damaged.
An O–Ring Maintenance Kit is provided with your pressure
washer which includes replacement o-rings, rubber washer
and water inlet filter. Refer to the instruction sheet
provided in the kit to service your unit’s o-rings. Note that
you will not use all of the parts in the kit.
To remove a worn or damaged o–ring; use a small flathead
screwdriver to get underneath the o-ring and pry it off.
Pump Oil Maintenance
This model does not require any pump maintenance.The
pump is pre-lubricated and sealed, requiring no additional
lubrication for the life of the pump.
ENGINE MAINTENANCE
See the engine operator’s manual for instructions on how
to properly maintain the engine.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Use wire here
to remove
debris
Figure 18 — Nozzle Maintenance
Figure 19 — Backflushing the Nozzle Extension
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
Avoid prolonged or repeated skin contact with used
motor oil.
CAUTION
• NEVER repair leaking connections with sealant of any kind.
Replace o-ring or seal.
The high pressure stream of water that this
equipment produces can pierce skin and its
underlying tissues, leading to serious injury and
possible amputation.
WARNING