Briggs & Stratton 01653, 01654, 01892, 01893 Portable Generator User Manual


 
7
Portable Generator
ELECTRIC START
Your unit may be equipped with electric start capability but
can be started manually. If you choose not to use the
electric start feature, you do not need to install the battery.
If your unit does not have electric start, ignore this section.
Check Battery / Attach Negative
Battery Wire
The sealed battery on the generator is fully charged and
pre–installed except for the negative (black) battery cable.
To install:
1. Cut off tie wrap securing loose end of negative (black)
cable.
2. Remove nut and washer on negative battery terminal.
3. Slide negative battery cable over screw on negative
terminal (Figure 3).
4. Reattach washer and nut and tighten.
5. Verify that connections to battery and generator are
tight and secure.
BEFORE STARTING THE
ENGINE
Add Engine Oil and Fuel
Place generator on a level surface.
Refer to engine owner’s manual and follow oil and fuel
recommendations and instructions.
NOTE: Check oil often during engine break–in. Refer to
engine owner’s manual for recommendations.
NOTE: The generator assembly rotates on a prelubricated
and sealed ball bearing that requires no additional
lubrication for the life of the bearing.
Figure 3 — Negative Battery Connection
Positive battery cable
Screw
Negative
battery
cable
Washer
Nut
CAUTION
Refer to engine manual for oil and fuel fill information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
Any attempt to crank or start the engine before it has
been properly filled with the recommended oil will result
in equipment failure.