Blue Rhino SV5100 Insect Control Equipment User Manual


 
Outdoor LP Gas Mosquito Exterminator Model No. SV5100
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Cleaning and Care
CAUTION: All cleaning and maintenance should be done when SkeeterVac
®
is cool
and with the fuel supply disconnected.
CAUTION: DO NOT clean any SkeeterVac
®
part in a self cleaning oven.
CAUTION: This SkeeterVac
®
should be thoroughly cleaned and inspected on a regular
basis.
CAUTION: Abrasive cleaners will damage this product.
Before Each Use:
1. Keep the SkeeterVac
®
area clean and free from any
combustible materials, gasoline, and other flammable
vapors and liquids.
2. Do not obstruct the flow of the combustion of LP and the
ventilation air.
3. Keep the ventilation opening(s) of the LP gas tank area
free and clear from debris.
4. See “Cleaning Instructions” for proper cleaning
instructions.
Cleaning Instructions / Routine Service
To ensure maximum performance and to lengthen the life of your SkeeterVac
®
device, perform
these steps each time your tank is empty. This model will consume a standard 20# LP gas
tank every 18-21 days.
Note: While unit is in use, check
the following every 2-3 days:
• Check WaveDrawer
®
and clean (if necessary).
• Check air passages for blockage.
1. Turn LP gas tank valve “OFF”.
2. Disconnect hose/regulator gas line from tank by turning knob counterclockwise.
3. Remove empty tank replace with full LP gas tank.
4. Slide WaveDrawer
®
cover onto WaveDrawer
®
.
5. Remove WaveDrawer
®
, empty and clean.
6. Slide WaveDrawer
®
back into place.
7. Remove WaveDrawer
®
cover.
8. Remove used TacTrap™ and dispose of properly.
9. Slide fresh TacTrap™ in place and remove protective paper.
10. Remove Finetune
®
cover by turning counterclockwise.
11. Remove used Finetune
®
lure (if necessary) and properly dispose.
Note: Finetune
®
Lure lasts 60 days.
12. Remove fresh Finetune
®
lure from package (if necessary). Dispose of packaging properly.
13. Place Finetune
®
lure back into holder with holes orienting upward.
14. Replace Finetune
®
cover.
15. Select the lure output by adjusting the Finetune
®
cover.
16. Check engine and gas lines for any sign of damage or missing parts. Repair any problems
before attempting to start.
17. Reconnect gas line to LP gas tank by turning knob clockwise.
18. Remove tank cover from empty LP gas tank and place on full LP gas tank.
19. Perform leak check.
20. Start following “Lighting” instructions.
21. Wash hands with soap and water.
Replacing Igniter Battery
If you do not hear a clicking sound when the igniter button
is depressed, the battery may have lost its charge. Replace
battery as follows:
1. Turn LP gas tank valve “OFF”.
2. Open battery compartment by turning cap on bottom of
engine counterclockwise.
3. Remove used battery and properly dispose.
4. Place fresh AA battery into compartment –
negative (–) end goes in first.
5. Secure cap by turning clockwise until it stops.
6. Start following “Lighting” instructions.
Battery Placement
LP Gas Tank Ventilation Area
Operating Instructions
Checking for Leaks
Tank/Gas Line Connection
Make 2-3 oz. of leak solution by mixing one part liquid
dishwashing soap with three parts water.
Make sure control knobs are off.
Turn LP gas tank “ON” at valve.
Spoon leak check solution at all “x” locations
If any bubbles appear turn LP gas tank “OFF”,
reconnect and re-test. If you continue to see bubbles
after several attempts, disconnect LP gas source and
contact 1.800.762.1142 for assistance.
If no bubbles appear after one minute turn tank
“OFF”, wipe away solution and proceed.
Placement
Properly positioning your SkeeterVac
®
device is
important to maximizing performance. Since the
SkeeterVac
®
device attracts mosquitoes it should be
placed at least 10 feet from your living areas.
Mosquitoes typically live in areas that are shady, wet
and/or moist. Determine the primary mosquito habitat
and place your SkeeterVac
®
device as close as possible
to it.
If you live in an area with consistent wind, place your
SkeeterVac
®
device upwind from the primary mosquito
habitat.
Maximum performance may require relocating your
SkeeterVac
®
device from time to time. To move, place
your foot on the cart base and tilt backward by holding the
handle. Pull to the new location.
FineTune
®
: Customizing the Lure Output
The amount of octenol your SkeeterVac
®
device dispenses
is important to maximizing performance. Some mosquito
species are highly attracted to octenol while others are less
attracted.
This product contains an easy-to-use feature that allows
you to customize the amount of octenol released to match
the species in your environment.
Note: Lure lasts 60 days.
1. Remove Finetune
®
cover by turning counterclockwise.
2. Remove foil seal from the Finetune
®
Lure.
3. Place Finetune
®
lure back into holder with holes orienting
upward.
4. Replace Finetune
®
cover.
5. Select the lure output by adjusting the Finetune
®
cover.
Lighting
CAUTION: Do not operate with WaveDrawer
®
cover
on the WaveDrawer
®
1. Read instructions before lighting.
2. Turn “ON” gas at LP gas tank.
3. Press and hold control valve button.
4. IMMEDIATELY press and hold igniter button down until
you hear a “POP” sound indicating ignition. Normally
occurs within 20 seconds.
5. Continue to hold control valve button for 30 seconds.
6. The needle on the engine gauge should begin to move
into the “Green” zone, the LED lights will be flickering
and the vacuum fan will be running with air flow out of
the engine bottom, indicating ignition is complete.
CAUTION: If engine fails to light, shut LP gas off at tank and wait 5 minutes before
attempting to restart the engine by following the lighting instructions.
Turning Off
Turn LP gas tank “OFF” by turning valve clockwise until it stops.
CAUTION: The gas supply must be turned off at the LP-gas tank when this outdoor
gas appliance is not in use.
X
X
X
X
X
LP Gas Tank Valve
Regulator/Hose Assembly Connection
Button Placement
Igniter
Button
Control Valve
Button
Battery
Lure Output: Half Open
Lure Output: Fully Open
Lure Output: Closed