Bissell 87K1 Greenhouse Kit User Manual


 
w w w . b i s s e l l . c o m
7
Troubleshooting
Reduced spray or no spray
Possible causes Remedies
1. Spray nozzle clogged 1. Clean spray nozzle
2. Clean water/solution tank empty 2. Check/fill tank
3. Clean water/solution tank insert clogged 3. Clean insert at bottom of clean water/solution tank
4. Pump needs priming 4. Gently lift clean water/solution tank while depressing
the spray trigger OR gently squeeze clean
tank while depressing spray trigger
Deep cleaner won't pick up cleaning solution
Possible causes Remedies
1. Tank release latch is not closed properly 1. Lift up the tank release latch and press down
firmly to make sure it is in place
2. Poor upholstery/carpet tool position 2. Reposition upholstery/carpet tool on surface,
follow recommended cleaning procedures
3. Dirty water/collection tank is full 3. Empty dirty water/collection tank
4. Upholstery/carpet tool brush worn 4. Replace with new brush
5. Excess solution in vacuum flex hose 5. Lift hose and point upwards to allow water
in hose to flow into the dirty water/collection tank
6. Incorrect cleaning formula 6. Use BISSELL 2X compact formulas only
Other maintenance or service not included in the manual should be performed
by an authorized service representative.
Replacement parts
Item Part No. Part Name
1 203-6651 Tough Stain Brush Tool
2 203-7646 Clean water/Solution Tank (includes cap and insert assembly)
3 203-7144 Dirty Water/Collection Tank (includes the airstack and float assembly)
4 203-7646 Quick Release Cord Wrap
5 203-7645 Vacuum Flex Hose Storage Bracket (includes screw for assembly)
6 203-7643 Vacuum Flex Hose Clip
7 203-5014 Bottle Cap & Insert Assembly
CLEANING FORMULAS
8 79B9E 473 mL. 2X Concentrate Little Green
Advanced Formula
9 74R7E 473 mL. 2X Concentrate Pet Stain for compact Advanced
Formula