Baldor PC1700RI Portable Generator User Manual


 
Operation 4-3MN2411
Operator Control Panel
Continued
DC Circuit Breaker Provide overcurrent protection for the DC Output terminals. When tripped, the plunger
will extend from the body of the breaker. Simply push the plunger in to reset the
breaker.
Note: If the breaker continues to trip, disconnect all loads and reset the breaker. If the breaker
trips with all loads disconnected, turn off the generator and discontinue use until the
generator is repaired.
Engine Switch Stop In this position, the engine is stopped and fuel supply line is closed.
Run Allows the engine to start and run during normal operation.
Choke Allows cold weather starting, place the Engine Switch in the Run position after
engine is started.
PreStart Checks
Before the engine is started, several things must first be checked.
1. Place the generator set in an open, dry, well ventilated and reasonably level location.
2. If grounding is required for your application, check to make sure your unit is grounded
properly (see Section 3).
3. Check the engine’s oil level, see Section 5.
4. Check the fuel level, see Section 5.
5. Disconnect or “turn off” all external loads.
6. Make sure DC circuit breaker is set (pushed in).
7. Tighten any bolts or nuts that may have loosened due to vibration.
8. Be sure all extension cords are in good condition before starting the generator.
Use only U.L. listed extension cords.
StartUp Procedure
1. Move the Engine Switch to the “Choke” position. If the engine is warm or if the ambient
air temperature is high; try starting the engine switch in the Run position.
2. Check the fuel system for fuel leaks and repair them prior to starting the engine.
3. Pull lightly on the recoil grip until you feel significant resistance, then pull sharply. Allow
the recoil to gently rewind into the recoil housing. Do not allow the recoil rope to “snap
back” into the recoil housing.
Note: If the engine does not start after turning the engine over a few times, smell for fuel near
the air cleaner. If there is a significant gasoline smell coming from the air cleaner, turn the
engine switch to the Run position and attempt to start the engine.
Note: If engine does not start using normal starting methods, check the oil level. The oil level
sensor will prevent engine operation if oil level is low.
4. When the engine starts, turn the engine switch to the Run position.
5. Turn the Auto Power Save switch to On so engine can idle (if equipped).
6. Ensure that the Pilot Lamp is on and the Overload Lamp is off. Otherwise stop engine
immediately and correct the problem.
7. Allow engine to run for 20 or 30 seconds with no load. (Warm up).
8. Power is now present at the receptacles.
Connect or “Turn On” the loads you wish to operate.
9. Turn the Auto Power Save switch to Off or On as desired.
WARNING: Never move a generator set that is running. Hazards are caused by moving a generator set
that is running.
Stopping Procedure
1. Disconnect or “Turn Off” all loads connected to the generator set.
2. Turn the Auto Power Save switch to On so engine can idle (if equipped).
3. Allow the generator to run at idle for 3 minutes with no load. (Cool down).
4. Move the engine switch to the Stop position.
WARNING: Parts of this generator are extremely hot during and after operation. To prevent severe burns,
do not touch any part of the generator until you have first determined if the part is hot. Wear
protective clothing and after use allow sufficient time for parts to cool before touching any
part of the generator.