Ariens 932037 - 724, 932036 - 524, 932504 - 524, 932505 - 724 Snow Blower User Manual


 
GB - 18
Ariens Dealers will provide any service or
adjustments which may be required to keep
your unit operating at peak efciency. Should
engine service be required, contact an Ariens
dealer or an authorized engine manufacturer's
service center.
SERVICE POSITION
Place unit on a at level surface. Tip unit
forward onto front of impeller housing for
service. Ensure unit is secure and will not tip
over. Strap and clamp onto bench if needed.
MAINTENANCE SCHEDULE
The chart below shows the recommended
maintenance schedule that should be
performed on a regular basis. More frequent
service may be required.
CHECK FASTENERS
Make sure all hardware is tightened properly.
CHECK CLUTCHES
Auger / impeller must stop within 3 seconds
when attachment clutch/impeller brake bail is
released.
Wheels must stop quickly when traction drive
clutch bail is released.
If clutches do not engage or disengage
properly, adjust or repair before operation (see
Service and Adjustments).
CLEAN ENGINE
Refer to Engine Manual for detailed
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked
every 5 hours of operation. Oil level MUST be
maintained in safe operating range on dipstick
at all times or engine damage will result (See
Engine Manual).
Park unit on a level surface. Refer to Engine
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after rst 2 hours of operation,
thereafter change oil every 25 hours (more
often if required). Refer to Engine Manual for
detailed instructions.
Run engine just prior to changing oil. Warm oil
will ow more freely and carry away more
contamination.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire
sidewall.
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be
maintained.
Gear cases are lled to the correct level at the
factory. Unless there is evidence of leakage,
no additional lubricant should be required.
Check oil level each season or every 25 hours
of operation.
To ensure adequate lubricant level:
1. Remove ller plug (Figure 9). Lubricant
must be at least up to bottom of lubricant
ller hole with unit resting on a level-
surface.
MAINTENANCE
WARNING: AVOID INJURY. Read
and understand the entire Safety
section before proceeding.
WARNING: Before tipping unit up
onto housing, remove fuel so no
spills will occur. Ensure unit is
secure and will not tip over during
maintenance.
MAINTENANCE SCHEDULE
Service
Performed
Each
Use
Every
5 hrs.
Every
25
hrs.
Yearly
Check
Fasteners
Check
Clutches
Clean Engine
Check Engine
Oil
Change
Engine Oil
*
Check Tire
Pressure
Check Auger
Gearcase
••
General
Lubrication
••
* After rst two hours of operation.