30
CONTINUITY DIAGRAM
Model 926500, 501
PS0841
The diagrams below show the various states of connection for electrical components.
The solid lines on switchs show continuity.
NOTE: All switches are viewed from the rear.
S
A
M
BR
G
S
A
M
BR
G
S
A
M
BR
G
OFF RUN START
HAND WARMER
OFF
HAND WARMER
ON
NOT ENERGIZED ENERGIZED
Key Switch
(02739600)
Hand Warmer Switch
(02485700)
Solenoid (Top View)
(03679000)