33
CONTINUITY DIAGRAM
Model 924300, 505, 506, 508
PS0841
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.
Hand Warmer Switch
(02485700)
HAND WARMER
OFF
HAND WARMER
ON
Key Switch
(02739600)
OFF START
M
A
S
R
B
G
RUN
M
A
S
R
B
G
M
A
S
R
B
G
Chute Motor Switch (Models 505, 506)
(02485600)
LEVER LEFT
CHUTE LEFT
LEVER RIGHT
CHUTE RIGHT
Solenoid (Top View)
(03679000)
NOT ENERGIZED ENERGIZED