Ariens 921012 Snow Blower User Manual


 
GB - 25
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be
maintained.
Gear cases are filled to the correct level at
the factory. Unless there is evidence of
leakage, no additional lubricant should be
required. Check oil level each season or
every 25 hours of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 25). Lubricant
must be at least up to bottom of lubricant
filler hole with unit resting on a level-
surface.
2. Add lubricant if required. Allow oil to
drain to level of plug and replace plug.
IMPORTANT: Use only Ariens special gear
lubricant L-2 (Part Number 00008000).
Gearcase filler plug may require an
application of Loc-Tite® 565 thread sealant
with repeated servicing.
GENERAL LUBRICATION
IMPORTANT: Wipe each fitting clean before
and after lubrication. Do not wipe gearcase
filler plug; wiping the gearcase filler plug may
remove thread sealant and cause leaks.
IMPORTANT: DO NOT allow grease or oil to
get on friction disc, friction plate or belts.
NOTE: Apply Ariens Hi-Temp Grease or
equivalent to the lubrication fittings. See
SERVICE PARTS on page 36.
Sno-Thro should be lubricated (Figure 26) at
beginning of season or every 25 operating
hours.
Figure 25
1. Auger Gearcase
2. Oil Fill and Drain Plug
2
1
OS7132
Figure 26
Oil
Grease
OS7136
OS7141
OS7142
921011, 012, 013, 014, 015,
016, 019, 020
921017, 018
921017, 018