Liquid Combustion
Technology
Oil Drain Tube Oil Seepage 9/28/2011
PROBLEM DEFINITION:
Oil Seepage from 35mm Drain Tube Reported by customer. After internal inventory audit, seepage was con-
firmed. Further Investigative Analysis determined:
35mm Oil Tube Face (crush washer engagement area) does not meet surface finish drawing specification of
6.3um
Short Term Corrective Action:
LCT recommends increasing drain bolt torque to 23lb-ft to allow crush washer to fill excessive ridges/valleys
caused by the out of specification surface finish:
 Capability study was conducted on 30pc of Oil Drain Tubes removed from inventory product
 Engines were filled with oil and monitored over a 24hr period
 5pcs of the 30 were observed to have an oil witness mark below oil drain bolt (35mm drain tube
side)
 Oil Drain Tubes were removed from engines and service Oil Drain Tubes (with correct surface fin-
ish) installed and torqued and engines were placed back into inventory
 Removed Oil Drain Plugs were then torqued to 23lb-ft and pressurized in a submerged state to
look for joint seal failure. No failures were observed after torque was increased to 23lb-ft
Long Term Corrective Action:
 Currently working with supplier to determine root cause of oil drain tube missing the facing operation
 Will update with full 8D report once final root cause has been determined
Containment Activities:
 Inventory audits were conducted with product in South Carolina warehouse
 Product with May 25th date code (>15000 engine serial number) was discovered to have the “non faced”
machining condition
 Product from August 6th (<8000 engine serial number in August) was discovered to have correct machined
face surface area
 Total engine exposure based on the 5/30 statistical sample—5689
30pc Oil Drain Tube Samples
- Samples were torqued to 23lb-ft
- Samples were pressurized and sub-
merged
- No leaks were detected