Aqua Products CC-350 Portable Generator User Manual


 
9
220Volt Circulation Pump With 220 Volt Chlorine Generator
120Volt Circulation Pump With 240 Volt Chlorine Generator
A 240 Volt Chlorine Generator may NOT be connected to a system with a 120 Volt circulation pump.
Wiring the Cell
Connect the two black wires from the Control Box to the two metal studs on the sides of the Cell and tighten
firmly with a screwdriver by hand. To avoid damage to the screws, DO NOT use a power screwdriver. Note
these wires are interchangeable. Push the plastic terminal covers up to cover the terminal connection until
they click into place. This will ensure a watertight connection.
Wiring the Flow Sensor
Find the two 18 AWG wires with the ¼” Quick connect terminals from the Cell cable and push them on their
respective connectors on the Flow Sensor. These wires are interchangeable.