3
INSTALL HANDLE
ADJUST HOT LIMIT STOP
By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).
1
5
1
3
1
1
9
7
5
3
1
0
1
5
1
3
1
1
9
7
5
3
1
1
5
1
3
1
1
9
7
5
3
1
4
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a
flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4) and
NUMBERS (5) on HOT LIMIT STOP (1) for indication.
1
5
1
5
4
4
3
3
2
2
1
2
3
4
Find correct position of HANDLE (1) and push
HANDLE (1) onto VALVE STEM (4).
Install HANDLE SCREW (2) and push in INDEX
CAP (3).
Check proper operation of HANDLE (1).
Turn on water supply on and test installed fitting.
Operate valve and diverter spout.
A
2
INSTALL TRIM
When finished tiling the wall, remove PLASTER GUARD (A)
and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4).
Remove PIPE CAPS (5) from shower pipe and tub filler pipe.
Install SHOWER ARM with FLANGE (6) and SHOWER HEAD (7).
Install TUB FILLER SPOUT with FLANGE (8).
6
7
3
1
4
5
2
5
8
CAUTION: Protect finish on SHOWER ARM,
SHOWER HEAD and TUB SPOUT when installing.
SHOWER ARM
FLANGE
SPOUT FLANGE
Off
Ho
t
Off
Hot
M968457B