American Standard 2397.202TC Hot Tub User Manual


 
H118
© 2008 AS America Inc.
PRINCETON™ RECESS BATH
WITH LUXURY LEDGE
AMERICAST
®
BRAND ENGINEERED MATERIAL
Revised 2/08
1524mm
(60)
864mm
(34)
32mm
(1-1/4)
FINISHED
WALL
19mm
(3/4)
FINISHED
WALL
C/L OF DRAIN
197mm
(7-3/4)
ROUGH
FLOOR
356mm
(14)
FINISHED
WALL
464mm
(18-1/4)
149mm
(5-7/8)
SEE FITTING SPECS
FOR DIMENSION
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
346mm
(13-5/8)
25mm
(1)
1651-1981mm
(65-78)
OPTIONAL
70mm
(2-3/4)
117mm
(4-5/8)
1-1/2 N.P.T.
THREADS
1-1/2 O.D.
TAILPIECE
102mm
(4)
64mm
(2-1/2)
305mm
(12)
SEE
NOTE
89mm
(3-1/2)
C/L OF
SUPPLIES
229mm x 305mm
(9 x 12) CUTOUT
TILING FLANGE
NOTE: Dimensions shown for 2394/2395 only. Refer to installation instruction for 2392/2393 above oor installation.
GENERAL SPECIFICATIONS FOR 2394/2395 BATHING POOL
60 x 34 x 14 In. (1524 x 864 x 356mm)
118 Lbs. (54 Kg.)
468 Lbs. (213 Kg.)
42 Gal. (159 L)
42 x 19 In. (1067 x 483mm)
56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
33 Lbs./Sq.Ft. (159 Kgs./Sq.m)
6.7
20.1
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
GENERAL SPECIFICATIONS FOR 2396/2397 BATHING POOL
60 x 34 x 17-1/2 In. (1524 x 864 x 445mm)
126 Lbs. (57 Kg.)
476 Lbs. (216 Kg.)
42 Gal. (159 L)
42 x 19 In. (1067 x 483mm)
56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
34 Lbs./Sq.Ft. (163 Kgs./Sq.m)
8.1
24.1
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
NOTES:
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS.
(2395.202).
SHOWN WITH POP-UP C.D. & O.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH FITTING.
CONCEALED PIPING NOT FURNISHED.
BATH FAUCET NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range
of tolerances established by ANSI Standard A112.19.4 These measurements are
subject to change or cancellation. No responsibility is assumed for use of
superseded or voided leaet.
STUD
SHIM
DRY WALL
TILE
SEALANT
TUB
ROOFING NAIL
STEEL
STUD
SHIM
DRY WALL
WASHER
TILE
SEALANT
TUB
4" (102mm)
DRYWALL
SCREW
WOOD STUDS STEEL STUDS
Below is shown typical cross sections of the tub
rim showing typical wall constructions.
51 x 102mm (2 x 4) WOOD
STRINGER FULL LENGTH
BARRIER FREE