WIRE SELECTION GUIDE
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings
are factory tightened and inspected, some loosening may have occurred during transit.) Make sure the whirlpool is
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or
stains may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB
Your new acrylic bathtub has been molded in the newest plumbing fixture material available today. Acrylics are
tough durable finishes that are simple and easy to care for.
The colors have been formulated to match other American-Standard fixtures and enhance your choice of
bathroom decorations. The high gloss surface is resistant to impact and chemicals and will retain its lasting
luster with proper care and maintenance.
AFTERCARE and CLEANING
Always fill the tub with temperate water. Excessively hot water may cause surface damage
Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray
or concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner,
or cleaning products in aerosol cans.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits, or other surface
blemishes.
Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses
its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and
waxing with a "liquid wax."
Do not wax areas where you walk or stand.
Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into
contact with the surface.
Clean the surrounding surface immediately after using caustic drain cleaners.
Burning cigarettes will damage the surface.
Should damage to the fixture occur, repairs can be made quickly and easily.
Your distributor or builder can provide details.
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Motor
Hi-Performance
Rating
50' 100'
120V Power Line
150' 200'
12 12 10 8
1.0
(4)
SPIC AND SPAN
®
IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE