American Standard 1749.218C Hot Tub User Manual


 
COLONY 5 X 42 w/INTEGRAL APRON
WHIRLPOOL AND BATHING POOL
HIGH GLOSS ACRYLIC
© 2004 American Standard Inc.
NOTES:
BATH TO BE INSTALLED ABOVE FLOOR LINE AS A RECESS INSTALLATION. SUPPORT OF BATH BY SUMP
BEDDING. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS (1749.118).
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by
ANSI Standards Z124.1 and A112.19.7.
These measurements are subject to change or cancellation. No
responsibility is assumed for use of superseded or voided pages.
60"
(1524 mm)
12"
(305 mm)
8-3/4"
(222 mm)
9"
(229 mm)
2-3/4"
(70 mm)
CUTOUT IN FLOOR FOR DRAIN
(6) JETS
(2) AIR VALVES
ACCESS TO PUMP/MOTOR
THROUGH REMOVABLE
FRONT ACCESS PANEL
ON/OFF
SWITCH
WATER RETENTION
FLANGE (3 SIDES)
C/L OF DRAIN
3/4"
(19 mm)
43-1/2"
(1105 mm)
42"
(1067 mm)
21"
(535 mm)
PUMP
FINISHED
WALL
C/L OF
SUPPLIES
SEE FITTING
SPECS FOR
D
IMENSIONS
18-1/2
(470mm)
REF.
DIM
1-1/4" WATER
RETENTION
FLANGE
(3 SIDES
& APRON)
19
(485mm)
1-1/2 O.D.TAILPIECE
BATH
SUPPORT
MATERIAL
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
FINISHED
WALL
TOP OF
DECK
2-3/4
(70mm)
12
(305mm)
OPT.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65 & 78
(1651 & 1981mm)
C/L OF
OVERFLOW
4
(102 mm)
C/L OF
SPOUT
TILING
FLANGE
C/L OF
VALVES
C/L OF
SHOWER ARM
2-3/4
(70mm)
4-5/8
(117mm)
1-1/2 N.P.T.M.
THREADS
UNDERSIDE
OF DECK
18-1/2
(470mm)
REF.
DIM
19
(485mm)
1-1/2 O.D.TAILPIECE
BATH
SUPPORT
MATERIAL
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
FINISHED
WALL
TOP OF
DECK
2-3/4
(70mm)
12
(305mm)
OPT.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65 & 78
(1651 & 1981mm)
C/L OF
OVERFLOW
4
(102 mm)
C/L OF
SPOUT
TILING
FLANGE
C/L OF
VALVES
C/L OF
SHOWER ARM
2-3/4
(70mm)
4-5/8
(117mm)
1-1/2 N.P.T.M.
THREADS
UNDERSIDE
OF DECK
60"
(1524 mm)
12"
(305 mm)
8-3/4"
(222 mm)
9"
(229 mm)
2-3/4"
(70 mm)
CUTOUT IN FLOOR FOR DRAIN
WATER RETENTION
FLANGE (3 SIDES)
C/L OF DRAIN
3/4"
(19 mm)
43-1/2"
(1105 mm)
42"
(1067 mm)
21"
(535 mm)
FINISHED
WALL
C/L OF
SUPPLIES
SEE FITTING
SPECS FOR
DIMENSIONS
1-1/4" WATER
RETENTION
FLANGE
(3 SIDES
& APRON)
GENERAL SPECIFICATIONS FOR 1749 WHIRLPOOL
60 x 42 x 19 In.(1525 x 1067 x 483mm)
112 Lbs. (50 Kg.)
714 Lbs. (324 Kg.)
72 Gal. (274 L)
52 Gal. (197 L)
44 x 23 In. (1120 x 585mm)
54 x 26 In. (1370 x 660mm)
13-5/8 In. (346mm)
41 Lbs./Sq.Ft. (193 Kgs./Sq.m)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.0 HP, 9.9 AMPS, 120V.PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
GENERAL SPECIFICATIONS FOR 1749 BATHING POOL
60 x 42 x 19 In.
(1525 x 1067 x 483mm)
92 Lbs. (42 Kg.)
714 Lbs. (324 Kg.)
72 Gal. (274 L)
44 X 23 In. (1120 x 585mm)
54 x 26 In. (1370 x 660mm)
13-5/8 In. (346mm)
41 Lbs./Sq.Ft. (193 Kgs./Sq.m)
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)