Air King AK130 Blower User Manual


 
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
1. Connect the ducting to the fan’s duct collar (Figure 4). Secure in
place using tape or screw clamp. Always duct the fan to the outside
through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE
IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF
INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A
QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not
require the removal of the fan’s blower assembly. If you choose to wire
the unit from the inside, you will need to remove the blower assembly
and internal wiring compartment. Both methods are equally effective.
1a. External Wire Compartment: Remove the wire compartment cover
screw and place cover in a secure place (Figure 5).
INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present.
In addition to the exhaust fan you should have:
1 - Grill
1 - Damper Assembly (attached)
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Choose the location for your fan. To ensure the best air and sound
performance, it is recommended that the length of ducting and the
number of elbows be kept to a minimum, and that insulated hard
ducting be used. Larger duct sizes will reduce noise and airflow
restrictions. This fan will require at least 8" of clearance in the ceiling
or wall, and will mount through drywall
up to 3/4" thick. The fan mounts between
16" or 24" on center joists using the 4
provided mounting rails.
3. Select the most convenient electrical
knockout and remove using a straight-
blade screw driver (Figure 1).
SECTION 2
New Construction
1. Install the side rails on the housing and position the housing next to
the joist. Line up housing so that it will be flush with the finished
ceiling. Secure the ends of the rails with screws or nails (not included)
to the joists and slide the housing into the final position (Figure 2).
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline onto
the ceiling material (Figure 3). Set housing aside and cut opening,
being careful not to cut or damage any electrical or other hidden
utilities. Install the side rails on the housing and position the housing
in the previously cut hole so that it is flush with the finished ceiling.
Secure the ends of the rails to the joists (Figure 2).
Figure 1
Figure 2
www.airkinglimited.com
210952009 Rev. B 2-06 2 of 8
Joist
Housing
Hanger Bar
Figure 3
Joist